Installation and Start-up Specifications

Backup Operation
In case of malfunction of a compressor, the system can continue to operate with other compressors in heating or cooling mode thanks to the dual compressor design.

The Start-up Control Function (8-48 HP)
In the cooling mode, service valve, cross-linking error of the refrigerant pipes or electrical wiring, or EEV operating status can be checked automatically by control function. This control function can be operated at 0-43 °C outside temperatures and 10-32 °C inside temperature with a dip switch on the outdoor unit card. This feature avoids errors due to potential assembly defects after a 15-30 minute test period prior to start-up.

Monitoring Function
Error display provides easy error detection. Via multi-point sensors, several error detections are notified and these error codes can easily be displayed through the screen located on the outdoor unit card.
Operating status can be checked on a PC screen by RS232C connection, located in outdoor unit electronic card in all KX6 / KXR6 models and all tests can properly be carried out by Mentor PC service software.

Ease of Maintenance
Maintenance service is provided easily and quickly thanks to separate fan and mechanical sections.

Blue Fin - Condenser Coating
Blue Fin Technology used in heat exchanger surface has increased corrosion resistance.

Less Refrigerant Usage
The with reduced so that The use of new generation refrigerant R410A has reduced the diameter of fluid pipes, as the result cost of piping has been significantly minimized.

KX6 HP 4 5 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48
Liquid Line ø9,52 ø12,7 ø15,88 ø19,05
Gas Line ø9,52 ø19,05 ø22,22 ø25,4[ø28,58] ø28,58 ø31,8[ø34,92] ø38,1[ø34,92]

If outdoor fails other outdoor will start to working

If outdoor fails other compressor will start to working
devreye-almada-kontrol-fonksiyonu
Control function running with dip switch
izleme-fonksiyonu
Placed on the Outdoor Unit Card Error Display Screen

izleme-fonksiyonu
Mentor PC Service Software by Operating Status controls Done